The best Side of Dp50rb
The best Side of Dp50rb
Blog Article
Website page 45 Return “Printer Support” website page, Decide on the corresponding assistance with the printer listing and improve the provider. The technique integrates drivers of HP printers, right after HP printers are connected, motorists might be put in routinely (about 10s).If vehicle set up fails, icon will Screen on the right reduced corner on the screen to warn you that handbook set up is necessary. Site forty six: Community Preset
Most four periods tasking for 1 transmitted beam, leading to fantastic time resolution and better body fee.
Get a whole and prolonged check out on the anatomical framework by means of panoramic imaging coupled with velocity sign and ahead/backward scan means earning scanning less of a challenge, smoother plus more controllable.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Click Agree and Proceed to simply accept cookies and go on to the internet site or click on More Information to determine detailed descriptions of the types of cookies and decide on whether or not to just accept certain cookies whilst on the website.
When you halt the scanning and the graphic capture, you'll want to power off the technique and disconnect the technique with the AC energy supply, then pull out AC electricity cables. Web page 109: Battery Connecting Board
Website page one hundred forty five Thoroughly clean user interface Resources: dry comfortable fabric, delicate soapy water Method: Use dry soft cloth to wash the surface from the process. If your technique is dirty, moisten the soft fabric with moderate soapy water and wipe off any stains. Use dry soft cloth to eliminate any dampness and permit all challenging surfaces to totally air-dry. Page 146: Cleanse The Peripherals
Discover greater diagnostic information by prolonged watch from the anatomical structure on all convex probes.
Permits utilization of various scanned angles to sort just one graphic, resulting in Increased contrast resolution and improved visualization
5.2.three Geometric positioning precision Longitudinal geometric positioning precision Take a look at Step: Do adjustments as the way in tests the utmost depth. Document the distance by 20mm each segment to the longitudinal targets line using the measurement caliper; Pick the value with the best mistake (to 20mm), compute the accuracy using the system underneath The measurement caliper should be positioned in the upper fringe of the concentrate on, Be aware:... Website page 79 Transverse geometric positioning accuracy Check Stage: Go over the scan surface area of the phantom with water Dp50rb login or pair gel, Carefully Call the probe with the scan area Regulate the depth, building the transverse targets being shown inside the image. Regulate the main target position for being posited beside the transverse targets (the regular is not apparent) Change parameters like obtain, TGC, creating each transverse targets being Obviously exhibited. Website page 80 five.five.2.four Blackout Location Exam Phase: Include the scan floor from the phantom with h2o or couple gel, gently Get hold of the probe Along with the scan area Modify the depth in a lower worth, and established the main target at the nearest spot to the scan floor. Decrease the worth of parameters like AP, Achieve until finally the history noise just could be found. Web page 81: Program Improve And Upkeep
Just after thriving link, the freshly additional community printer name will be proven from the printer driver listing. Notice: Ahead of hook up the network printer, make sure the ultrasound system plus the printer are in a similar community domain, as well as the network is Performing Typically. The IP handle along with the server name needs to be valid, e.g. Web page forty seven DICOM Location Enter the AE Title of the ultrasound process, port and PDU in accordance with the real problem, and then click [OK] to exit the display screen.
.. Page 161 The indicator on the printer Faults happen when the adapter turns orange, and the printing printer adapter runs. Disconnect and hook up the fails. electricity adapter, electricity about the printer adapter all over again, and verify whether the printing is normal following 1 moment. Webpage 163: Electrical Protection Inspection
Functionality Check 5.5.one Test Course of action Resolution Detection depth Geometric Place Precision Blackout region examination File the Test images 5.5.2 Examination Content material The graphic employed Here's only for reference, stick with the impression result in the true Notice: problem. Requirements: Display screen: established the contrast and brightness at the scientific software value (or even the default status) Procedure surroundings: dark space, simulating the scientific application surroundings. Site 76 In problem that the transverse resolution screening targets are horizontally displayed, report the nominal length of two targets that can be Evidently identified. Repeat the Procedure earlier mentioned with the transverse resolution tests targets at other depths. As revealed in figure under. Axial resolution ... Site seventy seven When using the convex probe, keep the transverse resolution tests targets to NOTE: be shown near the midline. When utilizing a linear probe with steer functionality, usually do not activate the steer purpose when execute the transverse resolution examination. Zoom during the location wherever the targets Positioned if required. The diameter of the concentrate on level at a specific depth is equal for the transverse resolution in the depth. Web page seventy eight five.
Mindray respects your privacy. We use cookies for a range of needs, for example Web page functionality, strengthening your expertise of our Internet site, setting up integration with social networking and helping concentrate on our promoting.
Observe: Be sure that you could pull out and push in to the IO board sockets vertically when pulling out and assembling the IO board assembly around the placement from the deal with. Eliminate panhead screws with washers M3X6 (4) utilized to protected the IO board, then you can just take out the IO board. Site 116 Remove panhead screws with washers (two M3X6) that are mounted on the leading unit, get out the upper baffle after which you can pull out two cables connecting the key board to the power module assembly.